<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-14 11-38-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 67 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.1 kHz 83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 62 kHz 19000 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,9 dBr 1,34 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Leopold Stokowski & His Symphony Orchestra "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 62 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/14 11.37.51 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,7 dBr MIN: -0,9 dBr AVE: 1,34 dBr % above 12,2 dBr: 0,0 Last value: 1,3 dBr (2024/08/14 11.37.51) 11.24 11.26 11.28 11.30 11.32 11.34 11.36 -1 0 1 2 3 4 Pm [dBr]